Flange telescopic butterfly valve

Products > Butterfly Valve > Flange telescopic butterfly valve

Flange telescopic butterfly valve

Product model: SD341X
Nominal diameter: DN50 ~ 2000 (mm)
Nominal pressure: PN0.6 ~ 1.6 (MPa),
Applicable temperature: X: -40 ℃ ~ 90 ℃; XF: -20 ℃ ~ 200 ℃ (soft seal) ; Carbon: -29 ℃ ~ 425 ℃ stainless -40 ℃ ~ 650 ℃ (hard seal)
suitable medium: water, air, natural gas, oil and weak corrosive fluid
drive: worm gear, electric, pneumatic, hydraulic
valve Body material: WCB, QT450-10, stainless steel
Contact purchase
shared:

Product Description:

Flange telescopic butterfly valve with automatic compensation pipeline thermal expansion and contraction convenient loading and unloading function, used in the temperature below 120 ℃, nominal pressure below 1.6MPa in the oil, chemical, power, paper, water supply and drainage and municipal construction and other industrial pipe The optimal device for regulating flow and carrying fluid.


Working principle:

Flange telescopic butterfly valve is divided into three types: 
 A, ordinary type: optional design according to the expansion of the design specifications installation, if you need to limit the bolt, please specify when designed. 
 B, fixed limit type: it can be telescopic, but also limit, with the telescopic part of the fixed up and not let the expansion and contraction of the function. It is characterized by more features, wider scope of application. 
 C, lengthened: it is the ordinary type of telescopic butterfly valve expansion section, so that the length of the user to meet the length of the required (not including the amount of expansion and contraction), which is characterized by the transformation of the old pipeline, the original pipeline valve needs to be updated Replacement, without the original pipeline on the connection part of the valve lining, can be replaced. Lengthened selection should also be considered when adding limit measures, please specify when the need to limit the design.
 

Features:

1, the sealing parts can be adjusted to replace, sealing performance and reliable.

2, unique structure, design flexibility, light weight, effort, opening and closing quickly.

3, telescopic butterfly valve can not only compensate for the temperature difference between the thermal expansion and contraction of the function, but also for the maintenance of the valve to facilitate the installation and replacement.
 

Installation Precautions:

1, flange expansion butterfly valve installation must be flat before, do not random bump, the operation is strictly prohibited to remove the bracket.

2, flange telescopic butterfly valve factory structure length is the minimum length, installation, pull to the installation length (ie design length).

3, when the length between the pipeline longer than the expansion valve installation length, please adjust the pipe spacing, do not force the expansion of butterfly valve, so as not to damage the butterfly valve.

4, flange telescopic butterfly valve can be installed in any installation, do the temperature compensation, when the pipeline is installed, the direction along the pipeline at both ends of the bracket, to prevent telescopic valve telescopic tube pulled out.
 

The main technical parameters:

Nominal diameter DN (mm)

50 ~ 2000

50 ~ 1600

Nominal pressure PN (MPa)

0.6

1.0

1.6

Seal test (MPa)

0.66

1.1

1.76

Strength test (MPa)

0.9

1.5

2.4

proper temperature

Soft seal

X: -40 ° C to 90 ° C; XF: -20 ° C to 200 ° C

Hard seal

Carbon steel: -29 ℃ ~ 425 ℃ stainless steel -40 ℃ ~ 650 ℃

Applicable media

Water, air, natural gas, oil and weakly corrosive fluids

Leakage rate

Meet the GB / T13927-92 standard

Drive mode

Worm gear, electric, pneumatic, hydraulic


Main parts materials:

Part Name

material

Body

WCB, QT450-10, stainless steel

Butterfly board

WCB, QT450-10, stainless steel

Valve shaft

2Cr13 stainless steel

Sealing ring

rubber

filler

Flexible graphite


Adoption of standards:

Manufacturing standards

JB / T8527-97, GB / T 122387-89

Flange standard

GB9113-2000, GB17241.6-1998

Inspection standards

GB / T 13927-92


 Picture .png
 

The main dimensions PN1.0MPa
DN 
(mm)
Manual deviceDD1dbCLn-d04-MHH1H2L1L2L3L4L5φWT 
(kg)
L0LmaxLmin
3003D-30/25044540037028572823022528-φ23M27959542267449178254104473300148
3503D-30/250505460429306430132127112-φ23M201048583315449178254104473300188
4003D-30/250565515480327031333328312-φ28M241120620350449178254104473300237
4503D-30/250615565530327633435430416-φ28M241190667373449178254104473300268
5003D-30/400670620582347634636631616-φ28M241280702428486178254130528300289
6003D-60/800780725682368939841836816-φ31M271409759450627196245162596400480
7003D-60/8008958407944011542544539520-φ31M271613885528627244245162596400645
8003D-120 // 150010159509014412045547542520-φ34M3017361013573635244295196711300818
9003D-120 // 15001115105010014612048550545524-φ34M3018601071639635270295196711300956
10003D-120 // 15001230116011125015049551546524-φ37M33210712347239552702962958073001277
12003D-120 // 15001455138013285617554256251228-φ40M366232613438339554552962958073001764
14003D-200/40001675159015306219561263258232-φ43M39299616681078127045538741410895004280
16003D-200/40001915182017506822064066061036-φ49M45324617781218127059838741410895004953
18003D-200/120002115202019507024571073068040-φ49M45372020441426162874538760213995007416
20003D-600/120002325223021507427077579574544-φ49M45385121151486163075041760213995009372